HiScreen MabSelect-色谱柱 -耗材-生物在线
HiScreen MabSelect

HiScreen MabSelect

商家询价

产品名称: HiScreen MabSelect

英文名称: HiScreen MabSelect

产品编号: 28-9269-73

产品价格: 0

产品产地: 美国

品牌商标: GE

更新时间: null

使用范围: null

上海基星生物科技有限公司
  • 联系人 :
  • 地址 : 上海市宝山区友谊路1506号东智广场1109室
  • 邮编 : 201900
  • 所在区域 : 上海
  • 电话 : 138****5983
  • 传真 : 021-50801884
  • 邮箱 : 342786402@qq.com

28-9269-73 HiScreen MabSelect 
28-9269-76 HiScreen MabSelectXtra
28-9269-77 HiScreen MabSelectSuRe
28-9269-78 HiScreen Capto Q
28-9269-79 HiScreen Capto S
28-9269-80 HiScreen Capto MMC
28-9269-81 HiScreen Capto Adhere
28-9269-82 HiScreen Capto DEAE
28-9269-84 HiScreen Butyl FF
28-9269-85 HiScreen Butyl-S FF
28-9269-86 HiScreen Octyl FF
28-9269-88 HiScreen Phenyl FF, high sub
28-9269-89 HiScreen Phenyl FF, low sub
28-9505-10 HiScreen Q FF
28-9505-11 HiScreen Q HP
28-9505-13 HiScreen SP FF
28-9505-15 HiScreen SP HP
28-9505-16 HiScreen Phenyl HP
28-9505-17 HiScreen IMAC FF
28-9782-43 HiScreen Blue FF
28-9782-44 HiScreen Ni FF
28-9924-72 HiScreen Capto Phenyl (high su
28-9924-74 HiScreen Capto Blue

HiScreen Capto IEX Columns

  • Prepacked ready to use columns with different Capto IEX media for convenient process development optimization
  • Ideal for parameter method optimization and parameter screening due to the 10 cm bed height
  • Easy connection in series to achieve 20 cm bed height
  • Small bed volume gives fast results and minimal sample/buffer consumption
  • Reproducible results, scalable to BioProcess columns packed with the same media using the same linear fluid velocity

HiScreen Capto IEX Columns

Technical Information


HiScreen Capto IEX columns are part of the process development platform available from GE Healthcare. Five prepacked HiScreen columns with Capto Q, Capto DEAE (strong and weak anion exchange, respectively), Capto S (strong cation exchange), Capto adhere (strong multimodal anion exchange) and Capto MMC (weak multimodal cation exchange) are available.

 

These columns are due to the small column volume, 4.7 ml and 10 cm bed height excellent tools for method optimization, parameter screening, robustness testing and convenient scaling up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale up.

 

If necessary, two columns can easily be connected in series to give a bed height of 20 cm.

 

Media prepacked in HiScreen Capto IEX columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.

 

Click here to view this image in high resolution
HiScreen Capto IEX columns, prepacked for convenient and robust process development.

 

TECHNICAL SPECIFICATIONS
Media  Capto Q
Capto S
Capto DEAE
Capto MMC
Capto adhere 
Column volume  4.7 ml 
Column dimension  0.77 × 10 cm 
Recommended flow rates  Capto Q, Capto SP, Capto DEAE: 1.2-2.7 ml/min (150-350 cm/h)
Capto adhere, Capto MMC: 1.2-2.3 ml/min (150-300 cm/h) 
Maximum flow rates  Capto Q, Capto SP, Capto DEAE: 6 ml/min (700 cm/h)
Capto adhere, Capto MMC: 4.7 ml/min (600 cm/h) 
Column hardware pressure limit   8 bar (0.8 MPa, 117 psi) 
Maximum pressure over the packed bed during operation, Dp†  3 bar (0.3 MPa, 44 psi) 
 

 

 

Click here to view this image in high resolution
Robustness study with overlay of absorbance curves at 280 nm for cycles 1, 5 and 10 using HiScreen Capto MMC. The differences in UV signal is due to the use of different sample preparations.

 

Dynamic binding capacity (DBC) for BSA on HiScreen Capto MMC after 1, 5, and 10 cycles
HiScreen Capto MMC DBC (mg BSA/ml media)
New column 40
After cycle 5 40
After cycle 10 41
Difference

 

3%

 

http://www.gelifesciences.com/aptrix/upp01077.nsf/Content/Products?OpenDocument&moduleid=167764