2-D QUANT KIT-蛋白检测-试剂-生物在线
2-D QUANT KIT

2-D QUANT KIT

商家询价

产品名称: 2-D QUANT KIT

英文名称: 2-D QUANT KIT

产品编号: 80-6483-56

产品价格: 0

产品产地: 美国

品牌商标: GE

更新时间: null

使用范围: null

上海基星生物科技有限公司
  • 联系人 :
  • 地址 : 上海市宝山区友谊路1506号东智广场1109室
  • 邮编 : 201900
  • 所在区域 : 上海
  • 电话 : 138****5983
  • 传真 : 021-50801884
  • 邮箱 : 342786402@qq.com

80-6483-37 SAMPLE GRINDING KIT
80-6483-56 2-D QUANT KIT
80-6483-75 MINI DIALYSIS KIT,1 KDA,250 UL
80-6483-94 MINI DIALYSIS KIT,1 KDA,2 ML
80-6484-13 MINI DIALYSIS KIT,8 KDA,250 UL
80-6484-32 MINI DIALYSIS KIT,8 KDA,2 ML
80-6484-51 2-D CLEAN-UP KIT
80-6484-70 SDS-PAGE CLEAN-UP KIT
80-6501-04 2-D FRACTIONATION KIT
80-6501-23 PROTEASE INHIBITOR MIX
80-6501-42 NUCLEASE MIX

http://www.gelifesciences.com/webapp/wcs/stores/servlet/productById/zh/GELifeSciences-us/80648356

2-D Quant Kit

2-D Quant Kit is designed for the accurate determination of protein concentration in samples prepared for electrophoresis techniques such as 2-D electrophoresis, SDS-PAGE, or IEF.

  • Accurately determine protein concentration in the presence of 2% SDS, 1% DTT, 8 M urea, 2 M thiourea, 4% CHAPS, 2% Pharmalyte, and 2% IPG Buffer.
  • Quantitatively precipitates proteins while leaving interfering substances behind.
  • Linear response in the range of 0 to 50 μg protein, with recommended sample volumes of 1 to 50 μl.

 

Common spectrophotometric methods of quantitating protein rely either on Coomassie dye binding or protein-catalyzed reduction of cupric (Cu2+) ion to cuprous (Cu+) ion. Dye-binding assays cannot be used in the presence of any reagent that also binds the dye. This includes carrier ampholytes and detergents such as PlusOne CHAPS, SDS, and Triton X-100. Assays that depend on the reduction of cupric ion cannot be used in the presence of reductants such as DTT, or in the presence of reagents that form complexes with cupric ion, such as thiourea or EDTA.

 

The 2-D Quant Kit procedure works by quantitatively precipitating proteins while leaving interfering substances behind. The assay is based on the specific binding of copper ions to protein. Precipitated proteins are resuspended in a copper-containing solution and unbound copper is measured with a colorimetric agent. The absorbance at 480 nm is inversely related to the protein concentration. The assay has a linear response to protein in the range of 0 to 50 μg and recommended sample volume is 1 to 50 μl.

Reagents tested for compatibility with the 2-D Quant Kit

Compound Tested : Concentration
SDS : 2% (w/v)
CHAPS : 4% (w/v)
Triton X-100 : 1% (w/v)
Pharmalyte pH 3-10 : 2% (v/v)
IPG Buffer pH 3-10 NL : 2% (v/v)
Tris : 50 mM
EDTA : 10 mM
DTT : 1% (65 mM)
2-Mercaptoethanol : 2% (v/v)
Urea : 8 M
Thiorea : 2 M
Glycerol : 30% (w/v)

2-D Quant Kit — Technical Specifications

Sample Volume Min. 1 μl
Sample Volume Max. 50 μl
Assay Conditions 480 nm
1 h
Linearity 0 - 50 μg
Storage Conditions 2 - 8°C
Kit Contents Precipitant 250 ml
Co-precipitant 250 ml
Copper solution 50 ml
Color reagent A 2 x 250 ml
Color reagent B 5 ml
BSA standard 5 ml (2 mg/ml)
Complete Packsize 500 Assays
Wetted Part No
Guidance The kit is used for quantitation of protein amount using a colorimetric assay.

The kit contains reagents sufficient for 500 individual assays