iWorx--Data Acquisition and Analysis for the Life
Data Acquisition and Analysis for the Life Sciences--iWorx, USA

iWorx provides integrated physiology teaching kits and a full range of advanced systems and components for physiology research.

iWorx teaching kits are complete teaching solutions, including rugged hardware, easy-to-use software, and professionally developed courseware compatible with the most popular physiology lab manuals.

iWorx advanced research solutions include high performance recording hardware, software, and components that accelerate tissue bath studies, hemodynamic research, cardiac electrophysiology, and other advanced research. In addition to data acquisition hardware, iWorx offers a full selection of signal conditioners, stimulators, transducers, electrodes, cables, and general-purpose laboratory equipment and accessories.

Teaching Tools
Human Physiology
Combination     Animal/Human     Physiology
Psychological     Physiology
Courseware
LabScribe Software
Newsletter
Web Based Labs
Web Resources
Customers


Research Tools
Cardiac Hemodynamics
Organ and Tissue Bath Studies
Isolated Perfused Heart
Epithelial
LabScribe Software

Cardiac Hemodynamics Research

Hemodynamics is the study of the dynamic behavior of blood as it flows around the heart, the lungs and the body. Pressure is generated in various parts of the heart as a result of this movement. These pressures can be measured and monitored through catheters whose tips are placed in the atria, pulmonary artery, or systemic arteries.

Hemodynamic studies require the measurement of pressure, flow, and electrical signals from the heart, and electrical signals from nerves, such as the vagus. iWorx has everything you need for research studies in hemodynamics, and associated studies in cardiac electrophysiology and cardiopulmonary function.

Unique Labscribe2 Software Saves Hours in Data Extraction Time
Using LabScribe's unique Regions of Interest and AutoMarking capabilities, you can easily record and extract data of interest, then export to your choice of analytical programs. Additionally, powerful built-in analyses; let you script custom routines using a choice of any scripting languages (including Matlab, Python, Dadisp Labview and even C++); or easily export data to Excel or other analytical programs. LabScribe's versatility saves hours in data extraction time.

QRS Complex of ECG






zoom image







Record and AutoMark the ECG, sending the calculations to the journal from where they can be exported easily to Excel or other analytical program for further analysis.

Blood Pressure Analysis, including LDEVP







zoom image






Record and AutoMark LDEVP, systolic and diastolic from a blood pressure curve, sending the calculations to the journal from where they can be exported easily to Excel or other analytical program for further analysis.

iWorx Features for Cardiovascular and Hemodynamic Recording








zoom image







Online Analysis
LabScribe2 software can calculate rate, systolic, diastolic and mean pressures, as well as dp/dt and integral from any raw data input in real time. All of the same functions can be applied offline, too.

Offline Analysis
All of the online functions can be applied offline. In addition, a series of functions applied from the Analysis window can be used to reduce raw data. Functions operate on a selection of data and return a single value, which can be written to the LabScribe2 Journal. Currently supported functions include: T1,Y1,T2,Y2,T2-T1 Y2-Y1, Maximum, Minimum, Maximum-Minimum, Mean, Mark, Count, Units, Standard Deviation, RMS, Maximum dV/dt, Minimum dV/dt, Mean dV/dt, dV1/dt, dV2/dt, Area, Integral, Absolute Value of Integral. Analysis window functions used in conjunction with the LabScribe2 Find command, can automatically analyze the entire record.

A unique Calculations Function allows the user to identify and make measurements from characteristic points of an ECG or blood pressure waveform.

Input/Output
The built-in stimulator allows delivery of a single, continuous, or train of pulses. Pulse durations, frequencies and amplitudes can be changed as the protocol is being delivered. The software also offers full control of digital I/O lines that can be used to count events, or control devices in the lab environment.

Display
The LabScribe2 software allows you to easily convert voltage to real units, such as mmHg or percent for pressure or flow measurements, respectively. The display allows you to toggle between a preferred Y-axis scaling (between 40 and 140 mmHg, for example) and the best view as determined by the AutoScale feature. Alternately, you can zoom-in or zoom-out by factors of two with a single mouse click. In a similar fashion, X-axis scaling can be expanded or compressed by factors of two with a single click.

Real Time Annotations
While recording, you can mark your data with text messages. These marks are searchable and appear in the field of data to which they apply. Marks are time locked to the record and can be used to Go To any marked region of the data.

Data Reduction
Data can be analyzed and reduced in the Analysis window. Here, selections of data can be averaged and written to a report. For example, the software can be instructed to break the record up into five-minute pieces, determine the average systolic or average heart rate for the data in each segment, and write those values to a report.

XY Window
Any two channels can be displayed in XY format, online or offline. LabScribe2 software supports area measurements and segment slopes from such plots. And, of course, you can save the plots as pictures or text.







zoom image














Export
All recorded data can be exported to either a text file or a picture (.png) making reports or posters much easier to create. Of course, you can always print your data from any window at any scale.

New NBK/214 Advanced Neurobiology Teaching Kit

The new iWorx Neurobiology Teaching Kit includes everything you need to conduct a comprehensive lab course that uses both extracellular and intracellular recording techniques to demonstrate important characteristics of excitable tissue.
The integrated kit includes:
iWorx 214 four channel computer interface with two built-in isolated biopotential amplifiers and a stimulator
ETH-3000 AC/DC extracellular differential amplifier with an input cable and a matching headstage
ETH-3100 intracellular electrometer with its own headstage and microelectrode holder
NBC-300 Nerve Bath Chamber
The latest LabScribe2 data recording software
Web-ready iWorx courseware in PDF, HTML, and hard copies



 
NBK/214
Learn more about the new NBK-214 kit, click here.
Order an NBK-214 kit, click here.
 

New NBK/214 Neurobiology Lab Manual


The new iWorx Neurobiology Laboratory Manual–Version 1 (P/N INBLMV1) is designed for use with the new NBK/214 Advanced Neurobiology Teaching Kit and provides a full semester of activities that teach students about the properties of excitable tissue, using both intracellular and extracellular recording techniques.
The experiments in the manual are designed to teach students about the properties of membranes and their potentials, action potentials, synapses, signal integration, synaptic potentials, ganglions, and receptor potentials. The manual also includes tutorials about the electrical circuits of excitable tissues and the instruments used to record from excitable tissue.
The manual is written for use with the new LabScribe2 data recording and analysis software, and it includes a tutorial experiment designed to acquaint users with the features of LabScribe2 that will be used in the other experiments in the manual.

 
 
LabScribe2 Main Window
A recording of two compound action potentials (CAPs) displayed on the LabScribe2 Main window. These CAPs were triggered by a pair of suprathreshold stimulus pulses delivered in rapid succession. The stimulus pulses were far enough apart that all the fibers in the nerve fired a second time, as indicated by the amplitude of the second CAP being the same height as the first CAP. This result occurred because all fibers were out of their refractory periods.





Full Size Image

LabScribe2 Analysis Window
A recording of a compound action potentials (CAP) displayed on the LabScribe2 Analysis window. This CAP was triggered by a suprathreshold stimulus pulse. The values for the measurements taken from the CAP using the cursors and the functions are displayed in the Journal window next to the data display window.
2007-11-1


Copyright 1999-2003 American Health & Medical Supply International Corp. Co., Ltd. All rights reserved.
美国总部:
35 Weaver Street, Scarsdale
New York 10583. U.S.A.
电话. 001-914-498-4158
传真: 001-914-725-0628
成都办事处:
成都市上东大街36号、新和.春禧时代12楼11号
邮编:610016
联系人: 张涛:13308099019